본문 바로가기
Biocomma

[Biocomma] Copure® MS 96-Well Solid Phase Extraction (SPE) Plates

by 래빗랩스(RabbitLabs) 2023. 11. 13.

[Biocomma]  Copure® MS 96-Well Solid Phase Extraction (SPE) Plates

free 96-Well Plate MHLB9603 Copure® MS HLB 96-well plate 3mg/600μL 1 PC/PK
MHLB9605 Copure® MS HLB 96-well plate 5 mg/600μL 1 PC/PK
MWAX9603 Copure® MS WAX 96-well plate 3 mg/600μL 1 PC/PK
MWAX9605 Copure® MS WAX 96-well plate 5 mg/600μL 1 PC/PK
MWCX9603 Copure® MS WCX 96-well plate 3 mg/600μL 1 PC/PK
MWCX9605 Copure® MS WCX 96-well plate 5 mg/600μL 1 PC/PK
MMAX9603 Copure® MS MAX 96-well plate 3mg/600μL 1 PC/PK
MMAX9605 Copure® MS MAX 96-well plate 5 mg/600μL 1 PC/PK
MMCX9603 Copure® MS MCX 96-well plate 3 mg/600μL 1 PC/PK
MMCX9605 Copure® MS MCX 96-well plate 5 mg/600μL 1 PC/PK
Regular 96-Well Plates MHLB9610 Copure® MS HLB 96-well plate 10 mg/1 mL,10 mg/2 mL 1 PC/PK
MHLB9630 Copure® MS HLB 96-well plate 30 mg/1 mL,30 mg/2 mL 1 PC/PK
MWAX9610 Copure® MS WAX 96-well plate 10 mg/1 mL,10 mg/2 mL 1 PC/PK
MWAX9630 Copure® MS WAX 96-well plate 30 mg/1 mL,30 mg/2 mL 1 PC/PK
MWCX9610 Copure® MS WCX 96-well plate 10 mg/1 mL,10 mg/2 mL 1 PC/PK
MWCX9630 Copure® MS WCX 96-well plate 30 mg/1 mL,30 mg/2 mL 1 PC/PK
MMAX9610 Copure® MS MAX 96-well plate 10 mg/1 mL,10 mg/2 mL 1 PC/PK
MMAX9630 Copure® MS MAX 96-well plate 30 mg/1 mL,30 mg/2 mL 1 PC/PK
MMCX9610 Copure® MS MCX 96-well plate 10 mg/1 mL,10 mg/2 mL 1 PC/PK
MMCX9630 Copure® MS MCX 96-well plate 30 mg/1 mL,30 mg/2 mL 1 PC/PK

 

Copure® MS 96-well SPE Plates are designed for high-throughput clinical mass spectrometry based on biocomma®special SPE sorbents and core accessories.
 

Copure® MS Series 96-well SPE Plates are designed for high-throughput clinical mass spectrometry based on biocomma®special SPE sorbents and core accessories.The special SPE sorbents have more uniform particle size,larger specific surface area, higher loading capacity, higher purity, and no background impurities. Copure® MS Series overcame the difficulties of complex matrix of biological samples and extremely low amount of target to achieve excellent purity, excellent stability and low background interference result to ensure the quality of analysis. Beside the products, we also provide applications as reference to address customer concerns. Our products have excellent recovery rate of steroid hormones, catecholamines,vitamins, etc.

Features

● MS Series HLB is a versatile, hydrophilic-lipophilic-balanced reversed-phase sorbent suitable for acidic, basic, and neutral compounds.
● MS Series MCX is a strong cation exchange reversed-phase sorbent with high selectivity for weakly basic compounds.
● MS Series MAX is a strong anion exchange reversed-phase sorbent with high selectivity for weakly acidic compounds.
● MS Series WCX is a weak cation exchange reversed-phase sorbent with high selectivity for strongly basic compounds.
● MS Series WAX is a weak anion exchange reversed-phase sorbent with high selectivity for strongly acidic compounds.

DVfree 96-Well Plates

● No dead volume structure design, no solvent residue,reduce analyte loss.
● 3-5 mg sorbent per well, suitable for extraction of trace substances.
● Trace sorbent evenly packed with better results consistency and reproducibility.
● No evaporation and reconstitution necessary due to elution volumes as low as 25 µL.
● Compatible with biocomma® positive pressure devices and most liquid-handling robotic systems for automated, reliable high-throughput solid phase extraction. Regular 96-Well Plates
● Classic 96-well plate design for greater versatility.
● Available in 10 mg, 30 mg, etc. with high sample loading to meet most customer needs.
● Compatible with biocomma® positive pressure devices and most liquid-handling robotic systems for automated, reliable high-throughput solid phase extraction.

Regular 96-Well Plates

● Classic 96-well plate design for greater versatility.
● Available in 10 mg, 30 mg, etc. with high sample loading to meet most customer needs.
● Compatible with biocomma® positive pressure devices and most liquid-handling robotic systems for automated, reliable high-throughput solid phase extraction.

Results
1. MS Series HLB 96-Well Plate recovery and stability results
As result, under different spiked concentrations, the four compounds have good recovery.
In this experiment, the results of target compound compared from different wells from different plates and batches. The result shows good stability.

2. MS Series WCX 96-well plate stability test


3. MS Series MCX 96-Well Plate recovery and stability results
As result, under different spiked concentrations, both T3 and T4 have good recovery.

In this experiment, the results of target compound compared from different wells from different plates and batches. The result shows good stability.